Since release 15, new radio (NR) system has explicitly proposed the concept of numerology, which is used to represent the scaling of subcarrier bandwidth, FFT size, etc.
Above all, a reference numerology is defined based on
Δsubc,refNFFT,ref=15 kHz,=2048.Accordingly, the sampling rate the sample duration can be written as
fs,refTs,ref=Δsubc,refNFFT,ref,=fs,ref1=Δsubc,refNFFT,ref1.Additionally, an extreme numerology is also defined based on
Δsubc,maxNFFT,max=480 kHz,=4096,Similarly, the sampling rate and sample duration can be expressed as
fs,maxTs,max=Δsubc,maxNFFT,max,=fs,max1=Δsubc,maxNFFT,max1.The ratio of the two sample durations above is denoted by
κ≜Ts,refTs,max≡64.Then, other configurations can be accordingly scaled relative to the reference numerology. Supported numerologies can be listed in the table below. For convenient reference, a numerology indicator is defined based on the subcarrier bandwidth, i.e.,
μ≜log2Δsubc,refΔsubc.| μ | Δsubc (kHz) | CP type |
|---|
| 0 | 15 | NCP |
| 1 | 30 | NCP |
| 2 | 60 | NCP/ECP |
| 3 | 120 | NCP |
| 4 | 240 | NCP |
Regarding frame structure, following hierarchy is adopted.
- A frame is comprised of 10 subframes.
- A subframe is comprised of Nslotsubframe,μ=2μ slots, where μ is a numerology indicator.
- A slot is comprised of Nsymbolslot symbols.
Nsymbolslot={14,12,NCP;ECP.An OFDM symbol without cyclic prefix (CP), comprised of NFFT samples, has duration Tsym=NFFTts=Δsubc1, where
- ts=fs1 is the duration of each sample;
- fs=ΔsubcNFFT is the sampling rate.
There are a couple types of CP.
- Normal CP (NCP) consists of NCP=144NFFT,refNFFT samples. Particularly, there are additional 16NFFT,refNFFTΔsubc,refΔsubc samples for 1st symbol in each slot.
- Extended CP (ECP) consists of NCP=512NFFT,refNFFT samples.