Numerology

Since release 15, new radio (NR) system has explicitly proposed the concept of numerology, which is used to represent the scaling of subcarrier bandwidth, FFT size, etc.

Above all, a reference numerology is defined based on

Δsubc,ref=15 kHz,NFFT,ref=2048.\begin{aligned}\Delta_{\mathrm{subc, ref}} &= 15 \text{ kHz},\\N_{\mathrm{FFT, ref}} &= 2048.\end{aligned}

Accordingly, the sampling rate the sample duration can be written as

fs,ref=Δsubc,refNFFT,ref,Ts,ref=1fs,ref=1Δsubc,refNFFT,ref.\begin{aligned}f_{\mathrm{s, ref}} &= \Delta_{\mathrm{subc, ref}} N_{\mathrm{FFT, ref}},\\T_{\mathrm{s, ref}} &= \frac{1}{f_{\mathrm{s, ref}}} = \frac{1}{\Delta_{\mathrm{subc, ref}} N_{\mathrm{FFT, ref}}}.\end{aligned}

Additionally, an extreme numerology is also defined based on

Δsubc,max=480 kHz,NFFT,max=4096,\begin{aligned}\Delta_{\mathrm{subc, max}} &= 480 \text{ kHz},\\N_{\mathrm{FFT, max}} &= 4096,\end{aligned}

Similarly, the sampling rate and sample duration can be expressed as

fs,max=Δsubc,maxNFFT,max,Ts,max=1fs,max=1Δsubc,maxNFFT,max.\begin{aligned}f_{\mathrm{s, max}} &= \Delta_{\mathrm{subc, max}} N_{\mathrm{FFT, max}},\\T_{\mathrm{s, max}} &= \frac{1}{f_{\mathrm{s, max}}} = \frac{1}{\Delta_{\mathrm{subc, max}} N_{\mathrm{FFT, max}}}.\end{aligned}

The ratio of the two sample durations above is denoted by

κ≜Ts,maxTs,ref≡64.\begin{aligned}\kappa \triangleq \frac{T_{\mathrm{s, max}}}{T_{\mathrm{s, ref}}} \equiv 64.\end{aligned}

Then, other configurations can be accordingly scaled relative to the reference numerology. Supported numerologies can be listed in the table below. For convenient reference, a numerology indicator is defined based on the subcarrier bandwidth, i.e.,

μ≜log⁡2ΔsubcΔsubc,ref.\begin{aligned}\mu \triangleq \log_{2} \frac{\Delta_{\mathrm{subc}}}{\Delta_{\mathrm{subc, ref}}}.\end{aligned}
μ\muΔsubc\Delta_{\mathrm{subc}} (kHz)CP type
015NCP
130NCP
260NCP/ECP
3120NCP
4240NCP

Regarding frame structure, following hierarchy is adopted.

  • A frame is comprised of 10 subframes.
  • A subframe is comprised of Nslotsubframe,μ=2μN_{\mathrm{slot}}^{\mathrm{subframe},\mu} = 2^{\mu} slots, where μ\mu is a numerology indicator.
  • A slot is comprised of NsymbolslotN_{\mathrm{symbol}}^{\mathrm{slot}} symbols.
Nsymbolslot={14,NCP;12,ECP.\begin{aligned}N_{\mathrm{symbol}}^{\mathrm{slot}} = \begin{cases} 14, & \text{NCP}; \\ 12, & \text{ECP}. \end{cases}\end{aligned}
  • An OFDM symbol without cyclic prefix (CP), comprised of NFFTN_{\mathrm{FFT}} samples, has duration Tsym=NFFTts=1ΔsubcT_{\mathrm{sym}} = N_{\mathrm{FFT}}t_{s} = \dfrac{1}{\Delta_{\mathrm{subc}}}, where

    • ts=1fst_{s} = \dfrac{1}{f_{s}} is the duration of each sample;
    • fs=ΔsubcNFFTf_{s} = \Delta_{\mathrm{subc}} N_{\mathrm{FFT}} is the sampling rate.
  • There are a couple types of CP.

    • Normal CP (NCP) consists of NCP=144NFFTNFFT,refN_{\mathrm{CP} }= 144 \dfrac{N_{\mathrm{FFT}}}{N_{\mathrm{FFT, ref}}} samples. Particularly, there are additional 16NFFTNFFT,refΔsubcΔsubc,ref16 \dfrac{N_{\mathrm{FFT}}}{N_{\mathrm{FFT, ref}}} \dfrac{\Delta_{\mathrm{subc}}}{\Delta_{\mathrm{subc, ref}}} samples for 1st symbol in each slot.
    • Extended CP (ECP) consists of NCP=512NFFTNFFT,refN_{\mathrm{CP}} = 512 \dfrac{N_{\mathrm{FFT}}}{N_{\mathrm{FFT, ref}}} samples.